All Products
DB-A Dragon Iso-Booster: Dragon: Phase III in and out, either side of full galvanic isolation
Dragon: Phase III in and out, either side of full galvanic isolation
NetworkDB-A

DB-A Dragon Iso-Booster

Network Power Where Your Site Needs It

At a Glance

The DB-A Dragon Iso-Booster extends the Pyrodigital network by regenerating the incoming data signal and restoring network power for the next section, while also providing galvanic isolation. Connect up to 40 firing modules on the internal battery, or up to 128 with the compatible external power supply.

2-year warrantyMade in Germany

Included Equipment

  • DB-A Dragon Iso-Booster
  • Universal Charger with country-specific mains wall plug
  • USB stick with Operating Instructions and FSK timecode files
  • Spare fuses

Operational Role

The DB-A Dragon Iso-Booster receives the incoming Pyrodigital network signal through a galvanically isolated input. It then regenerates that signal and adds power for the downstream network. On long cable runs, where voltage loss can become a limitation, this allows the network to continue without relying on heavier power-carrying cable. Suitable signal cables with smaller conductors can therefore be used in many long-run applications, reducing cable cost and handling requirements.

Its galvanically isolated input electrically separates the incoming network from the Dragon’s output network. The regenerated output has its own driver, thermal circuit breaker, and local power source.

A Dragon can be connected at available points throughout the Pyrodigital network, including after a long cable run or another network extension; it does not need to connect directly to the field controller. The internal battery supports up to 40 firing modules. With a compatible external power supply, the Dragon can support up to 128 modules and operate from mains power; contact us to confirm availability for your country.

System Compatibility

  • Field controllers: FC-A, FC-E Raptor and legacy Pyrodigital controllers, including FC3 and FC-1
  • Firing modules: FM-A and legacy Pyrodigital firing modules, including FM1–FM8
  • Accessories: Universal Case, Charger, External Power Supply
    The case and external power supply are optional.
  • Network integration: Connects at available points throughout the PD Network and can be combined with Falcon and FiberCON links

Manuals & Documentation

Technical Specifications

Function

Signal boosting
Receives the incoming Pyrodigital network signal and regenerates it through a powered output stage
Isolation
The network input is galvanically isolated from the output network; the output uses the Dragon’s local battery ground
Output driver
Dedicated Pyrodigital network output driver
Compatibility
Pyrodigital field controllers and firing modules, including legacy generations

Pyrodigital network

Network input
1, galvanically isolated from the output network
Network output
1, protected by a thermal circuit breaker
Output voltage
24 VDC nominal on the internal battery; dependent on the connected supply. Output active while the network input is powered
Firing-module capacity
Up to 40 on internal battery; up to 128 with the compatible external power supply
Maximum constant output current
3 A (72 W at 24 VDC)

Power

Internal battery type
Non-spillable Valve-Regulated Lead-Acid (VRLA)
Internal battery voltage
24 VDC (2 x 12 VDC in series)
Internal battery capacity
2.1 Ah
Maximum charge current
0.56 A at <29.4 VDC
Battery status
Charge-state indicator at power-up, with a low-battery warning below 10%
Supplied charger
Universal Charger, 100–240 VAC, 50–60 Hz, with country-specific mains wall plug
External power option
External Power Supply available separately for select countries

Environmental and physical

Operating temperature (electronics)
−20 °C to +85 °C
Operating temperature (batteries)
−20 °C to +55 °C